1 -A JUNE EIT ספר שירות WAV יחידות מפוח נחשון מעל תיקרות אקוסטיות

2 1. GENERAL OVERVIEW - TADIRAN FAN COILS WTN WGF -A JUNE EIT WAV - -

3 WATER FAN COIL. MODEL NAMES GENERAL - CONFIGURATION &RQILJXUDWLRQPRGHOQDPHVIRU)DQ&RLO $$$ %%% & ' ) ([ * RGHO :1 :*) :$ &RLO SLSHV 1XPEHURIURZV URZ URZV URZV URZV &RQWUROYDOYH 1RQH ZRZD\ KUHHZD\ &RQWURO 1 1RQH (OHFWURPHFKDQLFDO,/ (OHFWURQLF/RFDO, (OHFWURQLFZLWK HPRWHFRQWURO L]H± $LUIORZ&) $/ :1/< FIP FIP FIP FIP :*),QWCOROG YHUVLRQ1/< FIP FIP LGH LSH &RQQHFWLRQ / /HIW LJKW +HDWLQJ HOHPHQW (.: (.: (.: CONFIGURATION TABLE - TADIRAN WATER FAN-COILS -A JUNE EIT PRODUCT WTN WGF WAV X- Normal Configuration O- Optional MODEL Coil - No. of Raws Pipe - Side Connection Left; Right Control Valve (none); way; way Heating Element E1=1kW; E=kW; E=kW Control IR-remote; IL-electronic; M-mechanic; N-none L R E1 E E IR IL M N 1 X X O X O X O X X O X O X O X O X X O X O O X O X O X X O X O X O X O X X O X X X X X X O X X X X X X O X X X X X X O X X X X X X O X O X X O X X O X O X X O X X O X O O X X O X X O X O X X O 1 X X O X O X X O - -

4 טבלת נתונים WAV 1 1,,, 1, //1 1//. (.) /" /". אופציה - KW 1uF/V A *(*). (.1) // // WAV,,,, // 1//.. (.) /" /". אופציה - KW x x 1/ x / x 1/ () uf/v A *(*). (.) // // WAV - WAV WAV WAV,, 1,,,,,, 1,,,,1 // // // 1/1/1 /1/ // Rows / rows -optional /" diameter. (.) /" /".. אופציה - KW.1 (.) /" /".. אופציה - KW /V, Hz / Hz optional, 1ph uf/v uf/v A A צנטריפוגלי *(*) *. (.). (.) // // // // ניתן לשטיפה.1 (.) /" /". 1 אופציה - KW x x 1/ x / x 1/ 1 uf/v.. 1A *. (.) // // WAV,, 1,, // //..1 (.) /" /".. אופציה - KW 1 uf/v.. 1A *. (.) // // Btu/h Watt Btu/h Watt CFM m³/h l/h קוטר (מספר) m (ft ) in in GPM l/min Psi הספק סוג Normal E-Type mm (in) צבע Kg (Lb.) Volt/Hz/ph Watt mf/volt Amp. Amp. ברז תלת-דרכי או דו-דרכי + ברזי ניתוק אלקטרו מכני אלקטרו מכני ימין / שמאל פח אלוצינג (ניתן בהזמנה מראש לצביעה) () Type in in (mm) dba * ** ( // ) ( ) : () ( ) (E ) ( x x ) ( ) ( ) ( ) ( ) (OxL) * : ( // ) " ( // ). " -, " - *. " -, " - **. " 1- ". " 1- " -A JUNE EIT - -

5 מידות WAV- WAV- WAV- WAV- WAV- WAV-1 -A JUNE EIT הערות: קופסת חשמל - ניתנת להסרה; ברז אירי תלת דרכי - אופציונאלי. יש להשאיר מרווח לפחות ס מ מכל צד של היחידה לצורך התקנה ושרות. - -

6 WAV- Flow Rate [L/hr] Water 1 Water Flow vs. Total Capacity [Btu/Hr],, 1,, Temp rise *c. 1,,,,,, [GPM] Pressure Drop vs. Water Flow [GPM] 1 dp [KPa] [psi] -A JUNE EIT 1 Water Flow Rate [L/hr] - -

7 WAV- TOTAL COOLING CAPACITY ref. Twb=1*c Twin=*c dtw [*c] TCC [W] SENSIBLE COOLING CAPACITY Sensible Cooling Capacity [Watt] Twin=*c ref. Tdb=1*c dtw [*c] SCC [W] Tdb = ROOM DRY-BULB TEMPERATURE Twb = ROOM WET-BULB TEMPERATURE Twin = INLET WATER TEMPERATURE dtw = WATER TEMPERATURE CHANGE -A JUNE EIT Qspec Specific Heating Capacity 1 Water Flow [L/Hr] Qspec = Specific Heat Factor THC = Total Heating Capacity = Qspec x (Twin - Tdb) Twin = Inlet Water Temperatuer Tdb = Room (Dry-Bulb) Temperatuer - -

8 WAV- Flow Rate [L/hr] Water 1 1 Water Flow vs. Total Capacity [Btu/Hr],, 1,,, Temp rise *c 1,,,,,,,, [GPM] Pressure Drop vs. Water Flow [GPM] 1 1 -A JUNE EIT dp [KPa] 1 1 Water Flow Rate [L/hr] [psi] - -

9 WAV- TOTAL COOLING CAPACITY ref. Twb=1*c Twin=*c dtw [*c] TCC [W] SENSIBLE COOLING CAPACITY Sensible Cooling Capacity [Watt] Twin=*c ref. Tdb=1*c dtw [*c] SCC [W] Tdb = ROOM DRY-BULB TEMPERATURE Twb = ROOM WET-BULB TEMPERATURE Twin = INLET WATER TEMPERATURE dtw = WATER TEMPERATURE CHANGE -A JUNE EIT Qspec Specific Heating Capacity 1 1 Water Flow [L/Hr] Qspec = Specific Heat Factor THC = Total Heating Capacity = Qspec x (Twin - Tdb) Twin = Inlet Water Temperatuer Tdb = Room (Dry-Bulb) Temperatuer - -

10 WAV- [L/hr] Flow Rate Water 1 Water Flow vs. Total Capacity Btu/Hr,, 1,,,, Temp rise *c,,,, GPM Pressure Drop vs. Water Flow [GPM] 1 1 dp [KPa] [psi] -A JUNE EIT Water Flow Rate [L/hr] - -

11 WAV- TOTAL COOLING CAPACITY Twin=*c ref. Twb=1*c dtw [*c] TCC [W] SENSIBLE COOLING CAPACITY Sensible Cooling Capacity [Watt] Twin=*c ref. Tdb=1*c dtw [*c] SCC [W] Tdb = ROOM DRY-BULB TEMPERATURE Twb = ROOM WET-BULB TEMPERATURE Twin = INLET WATER TEMPERATURE dtw = WATER TEMPERATURE CHANGE -A JUNE EIT Qspec Specific Heating Capacity Water Flow [L/Hr] Qspec = Specific Heat Factor THC = Total Heating Capacity = Qspec x (Twin - Tdb) Twin = Inlet Water Temperatuer Tdb = Room (Dry-Bulb) Temperatuer - -

12 WAV- [L/hr] Flow Rate Water 1 Water Flow vs. Total Capacity Btu/Hr,,,, Temp rise *c..... GPM.,,,,,, 1, Pressure Drop vs. Water Flow [GPM] dp [KPa] [psi] -A JUNE EIT 1 Water Flow Rate [L/hr] - -

13 WAV- TOTAL COOLING CAPACITY Twin=*c ref. Twb=1*c dtw [*c] TCC [W] SENSIBLE COOLING CAPACITY Sensible Cooling Capacity [Watt] Twin=*c ref. Tdb=1*c dtw [*c] SCC [W] Tdb = ROOM DRY-BULB TEMPERATURE Twb = ROOM WET-BULB TEMPERATURE Twin = INLET WATER TEMPERATURE dtw = WATER TEMPERATURE CHANGE -A JUNE EIT Qspec Specific Heating Capacity 1 Water Flow [L/Hr] Qspec = Specific Heat Factor THC = Total Heating Capacity = Qspec x (Twin - Tdb) Twin = Inlet Water Temperatuer Tdb = Room (Dry-Bulb) Temperatuer - -

14 WAV- [L/hr] Flow Rate Water 1 Water Flow vs. Total Capacity Btu/Hr,,,,, Temp rise *c GPM,,,,,, 1,. Pressure Drop vs. Water Flow [GPM] 1 -A JUNE EIT dp [KPa] 1 Water Flow Rate [L/hr] [psi] - 1 -

15 WAV- TOTAL COOLING CAPACITY Twin=*c ref. Twb=1*c dtw [*c] TCC [W] SENSIBLE COOLING CAPACITY Sensible Cooling Capacity [Watt] Twin=*c ref. Tdb=1*c dtw [*c] SCC [W] Tdb = ROOM DRY-BULB TEMPERATURE Twb = ROOM WET-BULB TEMPERATURE Twin = INLET WATER TEMPERATURE dtw = WATER TEMPERATURE CHANGE -A JUNE EIT Qspec Specific Heating Capacity 1 Water Flow [L/Hr] Qspec = Specific Heat Factor THC = Total Heating Capacity = Qspec x (Twin - Tdb) Twin = Inlet Water Temperatuer Tdb = Room (Dry-Bulb) Temperatuer - 1 -

16 WAV-1 Flow Rate [L/hr] Water 1 Water Flow vs. Total Capacity Btu/Hr,,,,, Temp rise *c GPM,,,,,, 1, 1,. Pressure Drop vs. Water Flow [GPM] 1 dp [KPa] [psi] -A JUNE EIT 1 Water Flow Rate [L/hr] - 1 -

17 WAV-1 TOTAL COOLING CAPACITY Twin=*c ref. Twb=1*c dtw [*c] TCC [W] SENSIBLE COOLING CAPACITY Sensible Cooling Capacity [Watt] Twin=*c ref. Tdb=1*c dtw [*c] SCC [W] Tdb = ROOM DRY-BULB TEMPERATURE Twb = ROOM WET-BULB TEMPERATURE Twin = INLET WATER TEMPERATURE dtw = WATER TEMPERATURE CHANGE Specific Heating Capacity -A JUNE EIT Qspec 1 Water Flow [L/Hr] Qspec = Specific Heat Factor THC = Total Heating Capacity = Qspec x (Twin - Tdb) Twin = Inlet Water Temperatuer Tdb = Room (Dry-Bulb) Temperatuer - 1 -

18 l/s Air Flow Rate VS. Static Pressure WAV Pa WG" High Speed Medium Speed Low Speed l/s Air Flow Rate VS. Static Pressure WAV -A JUNE EIT Pa WG" High Speed Medium Speed Low Speed - 1 -

19 l/s Air Flow Rate VS. Static Pressure WAV 1 Pa WG" High Speed Medium Speed Low Speed l/s Air Flow Rate VS. Static Pressure WAV -A JUNE EIT 1 Pa WG" High Speed Medium Speed Low Speed - 1 -

20 l/s Air Flow Rate VS. Static Pressure WAV 1 Pa WG" High Speed Medium Speed Low Speed l/s Air Flow Rate VS. Static Pressure WAV 1 -A JUNE EIT Pa WG" High Speed Medium Speed Low Speed - -

21

180 Prime Emissions level: EPA NSPS Stationary Emergency Tier 3

180 Prime Emissions level: EPA NSPS Stationary Emergency Tier 3 Generator set data sheet Model: Frequency: Fuel type: kw rating: DGGAE 60 Hz Diesel 200 Standby 180 Prime Emissions level: EPA NSPS Stationary Emergency Tier 3 Exhaust emission data sheet: Exhaust emission

More information

Generator set data sheet. 80 Prime Emissions level: EPA Nonroad Tier 1. Fuel consumption. Engine Standby rating Prime rating Continuous rating

Generator set data sheet. 80 Prime Emissions level: EPA Nonroad Tier 1. Fuel consumption. Engine Standby rating Prime rating Continuous rating Generator set data sheet Model: Frequency: Fuel type: kw rating: DGDB 50 Hz Diesel 85 Standby 80 Prime Emissions level: EPA Nonroad Tier 1 Exhaust emission data sheet: Exhaust emission compliance sheet:

More information

135 Prime Emissions level: EPA NSPS Stationary Emergency Tier 3

135 Prime Emissions level: EPA NSPS Stationary Emergency Tier 3 Generator set data sheet Model: Frequency: Fuel type: kw rating: DQGAC 60 Hz Diesel 150 Standby 135 Prime Emissions level: EPA NSPS Stationary Emergency Tier 3 Exhaust emission data sheet: Exhaust emission

More information

Generator set data sheet. 410 Prime Emissions level: EPA Nonroad Tier 1. Fuel consumption. Engine Standby rating Prime rating Continuous rating

Generator set data sheet. 410 Prime Emissions level: EPA Nonroad Tier 1. Fuel consumption. Engine Standby rating Prime rating Continuous rating Generator set data sheet Model: Frequency: Fuel type: kw rating: DGDB 60 Hz Diesel 100 Standby 410 Prime Emissions level: EPA Nonroad Tier 1 Exhaust emission data sheet: Exhaust emission compliance sheet:

More information

1400 Prime 1125 Continuous Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft

1400 Prime 1125 Continuous Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft Generator set data sheet Model: Frequency: Fuel type: kva : DQGAH 50 Hz Diesel 1540 1400 1125 Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft Exhaust emission data sheet: Exhaust emission

More information

Standby rating. Turbocharged and low temperature after-cooled

Standby rating. Turbocharged and low temperature after-cooled Generator set data sheet Model: Frequency: Fuel type: kva : DQGAN 50 Hz Diesel 1400 1275 1025 Emissions level: EPA NSPS Stationary emergency tier 2 2g TA Luft Exhaust emission data sheet: Exhaust emission

More information

1540 Prime 1250 Continuous Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft

1540 Prime 1250 Continuous Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft Generator set data sheet Model: Frequency: Fuel type: kva : DQGAG 50 Hz Diesel 1700 1540 1250 Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft Exhaust emission data sheet: Exhaust emission

More information

Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft

Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft Generator set data sheet Model: DQKAJ Frequency: 50 Hz Fuel type: Diesel kva rating: 2500 Standby 2000 Prime Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft Exhaust emission data sheet:

More information

Emissions level: EPA NSPS Stationary Emergency Tier 2

Emissions level: EPA NSPS Stationary Emergency Tier 2 Generator set data sheet Model: DQPAA Frequency: 60 Hz Fuel type: Diesel kw rating: 600 Standby Emissions level: EPA NSPS Stationary Emergency Tier 2 Exhaust emission data sheet: Exhaust emission compliance

More information

Non-Ducted Indoor Compressor Type DC Inverter Driven Rotary Rated Cooling Capacity BTUH RLA 10.8

Non-Ducted Indoor Compressor Type DC Inverter Driven Rotary Rated Cooling Capacity BTUH RLA 10.8 Submittal Data: Multi-Room Ductless heat-pump systems 18,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 9,000 BTUH. Rev. 1.3

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 9,000 BTUH. Rev. 1.3 MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 9,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 9,000 BTUH Multiaqua Model

More information

MHWW-18-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 18,000 BTUH. Rev. 1.3

MHWW-18-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 18,000 BTUH. Rev. 1.3 MHWW-18-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 18,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 18,000 BTUH Multiaqua Model

More information

MHWW-12-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 12,000 BTUH. Rev. 1.3

MHWW-12-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 12,000 BTUH. Rev. 1.3 MHWW-12-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 12,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 12,000 BTUH Multiaqua Model

More information

Multi-Room Ductless heat-pump systems Submittal Data: MULTI18HP230V1CO 18,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date

Multi-Room Ductless heat-pump systems Submittal Data: MULTI18HP230V1CO 18,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Multi-Room Ductless heat-pump systems Submittal Data: 18,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Reference Approval Construction Unit Designation

More information

Multi-Room Ductless heat-pump systems Submittal Data: MULTI24HP230V1CO 24,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date

Multi-Room Ductless heat-pump systems Submittal Data: MULTI24HP230V1CO 24,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Multi-Room Ductless heat-pump systems Submittal Data: 24,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Reference Approval Construction Unit Designation

More information

CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH

CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 2-Pipe Nominal Size: 60,000

More information

SEC 10 Fan Coil Units

SEC 10 Fan Coil Units 10 Fan Coil Units T31 10 version Dimensions, Weight, Water content C 170 160,5 C 160,5 630 530 100 100 71 15 133 Feet optional extra COL CONNECTONS PCKGNG row coils Heating additional coil (1 row) Ø 1/"

More information

Large University Central Chiller Plant Design Considerations

Large University Central Chiller Plant Design Considerations Carrier Engineering Newsletter Volume 5, Issue 3 Large University Central Chiller Plant Design Considerations Large campus chilled water plants have unique constraints and need careful evaluation for successful

More information

Field Accuracy of Temperature Measurements in TAB Work Andrew P. Nolfo, PE

Field Accuracy of Temperature Measurements in TAB Work Andrew P. Nolfo, PE Field Accuracy of Temperature Measurements in TAB Work Andrew P. Nolfo, PE The purpose of this article is to discuss the measuring and reporting of temperatures at heat transfer equipment during the Testing

More information

Air-Water Systems. Chilled Ceilings and Beams TROX USA. Principle of Operation. Radiant Effect on Occupants. Early 1980 s. Chilled Ceiling Panels

Air-Water Systems. Chilled Ceilings and Beams TROX USA. Principle of Operation. Radiant Effect on Occupants. Early 1980 s. Chilled Ceiling Panels Air-Water Systems and Beams Early 1980 s 1980 1990 2005 Buildings well insulated for heating Advent of personal computers Need to remove heat from space Limited space available TROX USA 1 2 Principle of

More information

Modular Active Chilled Beams

Modular Active Chilled Beams Modular Active Chilled Beams Presented by: Darren Alexander, P.Eng. Modular Active Chilled Beams Current System Solutions Fan Coil Units - Medium/High energy, medium noise solution. Output = 100-200 w/m

More information

Managing. Delta T in Buildings

Managing. Delta T in Buildings dp(ft) 83 dp (ft) 35 dp (ft) 41 105 140 180 188 1,800 GPM Tout(F)= 50 Tin (F)= 40 9000 MBH Managing Tout(F)= 50 1,800 GPM AHU 2 Delta T in Buildings Tout(F)= 50.0 1,800 GPM 192.5 FT 5,400 GPM 77 309 HP

More information

Utilities Infrastructure Cooling Distribution. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc.

Utilities Infrastructure Cooling Distribution. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. Utilities Infrastructure Cooling Distribution APPA Institute for Facilities Management Dallas Jan 2017 Bill Nelson PE 1 Purpose of Today s Presentation To provide a broad understanding of Chilled water

More information

COOLING TECHNOLOGY INSTITUTE

COOLING TECHNOLOGY INSTITUTE PAPER NO: TP08-16 CATEGORY: DRY COOLING COOLING TECHNOLOGY INSTITUTE THE COST OF NOISE ROBERT GIAMMARUTI HUDSON PRODUCTS CORPORATION JESS SEAWELL COMPOSITE COOLING SOLUTIONS, LLC The studies and conclusions

More information

Cooling coil optimisation in hot and humid climates for IAQ and energy considerations

Cooling coil optimisation in hot and humid climates for IAQ and energy considerations Cooling coil optimisation in hot and humid climates for IAQ and energy considerations Chandra Sekhar 1, Uma Maheswaran 2 1 Department of Building, National University of Singapore 2 Jurong Consultants

More information

Figure Heat pump model validation in heating mode: power consumption percentage error between model and experiment

Figure Heat pump model validation in heating mode: power consumption percentage error between model and experiment Percent Error 20% 18% 16% 14% 12% 10% 8% 6% 4% 2% Deviation by Uncertainty Analysis RMS Error (10:00 AM -- 11:30 AM):12.1% 0% 9:07 9:50 10:33 11:16 12:00 Time Figure 7.30. Heat pump model validation in

More information

Hourly Analysis Program v.4.1 Page 1 of 1

Hourly Analysis Program v.4.1 Page 1 of 1 Air System Design Load Summary for Zona 11 DESIGN COOLING DESIGN HEATING COOLING DATA AT Dec 1700 HEATING DATA AT DES HTG COOLING OA DB / WB 33.1 C / 23.5 C HEATING OA DB / WB -0.6 C / -3.2 C Sensible

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-GV Outdoor Unit RX-GV TABLE OF CONTENTS RX-GV Features............................................................. 2 2 Specifications.......................................................

More information

Lab # Waukesha Displacement Pumps

Lab # Waukesha Displacement Pumps Lab # BAEN /CHEN-422-622! 1 Pump Selection Waukesha Displacement Pumps Waukesha Positive Displacement Pump - Sanitary Bio-ethanol Bio-fuel flow chart BAEN /CHEN-422-622! 2 Summary Summary The selection

More information

Technical Specification Industrial Series - IS2 to IS48 Systems. CapDI Benefits. Feed Water Quality. Design and Scope of Supply.

Technical Specification Industrial Series - IS2 to IS48 Systems. CapDI Benefits. Feed Water Quality. Design and Scope of Supply. Technical Specification Industrial Series - IS2 to IS48 Systems Voltea s Industrial Series IS systems employ a simple, cost effective modular design providing flexibility to align with both current and

More information

Hourly Analysis Program v.4.1 Page 1 of 1

Hourly Analysis Program v.4.1 Page 1 of 1 Air System Design Load Summary for Zona 6 DESIGN COOLING DESIGN HEATING COOLING DATA AT Feb 1600 HEATING DATA AT DES HTG COOLING OA DB / WB 34.5 C / 23.7 C HEATING OA DB / WB -0.6 C / -3.2 C Sensible Latent

More information

Chilled Water Fan Coil. Ceiling Concealed Type. Vicot Air Conditioning Co., Ltd

Chilled Water Fan Coil. Ceiling Concealed Type. Vicot Air Conditioning Co., Ltd Chilled Water Fan Coil Ceiling Concealed Type Vicot Air Conditioning Co., Ltd ABOUT US Vicot Group is a high-tech corporation specialized in R&D, production, sales and service of renewable energy products.

More information

Sub Wet-Bulb Evaporative Chiller

Sub Wet-Bulb Evaporative Chiller Emerging Technologies Sub Wet-Bulb Evaporative Chiller Prepared by: Emerging Products Customer Service Southern California Edison June 2015 Acknowledgments Southern California Edison s Emerging Products

More information

Chilled Water Distribution Systems. APPA Institute for Facilities Management New Orleans, LA January 19, 2016

Chilled Water Distribution Systems. APPA Institute for Facilities Management New Orleans, LA January 19, 2016 Chilled Water Distribution Systems APPA Institute for Facilities Management New Orleans, LA January 19, 2016 1 Purpose of Today s Presentation To provide a broad understanding of chilled water distribution

More information

Existing Building Cx: Processes & Results A Cultural Journey. Barry Abramson Senior Vice President Servidyne

Existing Building Cx: Processes & Results A Cultural Journey. Barry Abramson Senior Vice President Servidyne Existing Building Cx: Processes & Results A Cultural Journey Barry Abramson Senior Vice President Servidyne AIA Quality Assurance Learning Objectives 1. Define the key steps in the process of retrocommissioning

More information

Hourly Analysis Program v.4.1 Page 1 of 1

Hourly Analysis Program v.4.1 Page 1 of 1 Air System Design Load Summary for Zona 9 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jan 1400 HEATING DATA AT DES HTG COOLING OA DB / WB 34.5 C / 23.7 C HEATING OA DB / WB -0.6 C / -3.2 C Sensible Latent

More information

THE GREAT CHILLED WATER DEBATE. Michael Dagher

THE GREAT CHILLED WATER DEBATE. Michael Dagher THE GREAT CHILLED WATER DEBATE ichael Dagher Central Chiller Plant Direct-Primary, Variable Flow? Variable Primary / Variable Secondary (Decoupled)? Parallel Vs Series Counterflow? Pressure Control? What

More information

Hourly Analysis Program v.4.1 Page 1 of 1

Hourly Analysis Program v.4.1 Page 1 of 1 Air System Design Load Summary for Zona 3 Project Name: Av. Cabildo 3067, 4 piso 02/13/2011 DESIGN COOLING DESIGN HEATING COOLING DATA AT Feb 1500 HEATING DATA AT DES HTG COOLING OA DB / WB 34.9 C / 23.8

More information

Hourly Analysis Program v.4.1 Page 1 of 1

Hourly Analysis Program v.4.1 Page 1 of 1 Air System Design Load Summary for Zona 8 DESIGN COOLING DESIGN HEATING COOLING DATA AT Dec 1700 HEATING DATA AT DES HTG COOLING OA DB / WB 33.1 C / 23.5 C HEATING OA DB / WB -0.6 C / -3.2 C Sensible Latent

More information

Agenda. Understanding the three basic piping systems. Low DeltaT Syndrome causes, effects, and solutions Design & Control Considerations (VPF)

Agenda. Understanding the three basic piping systems. Low DeltaT Syndrome causes, effects, and solutions Design & Control Considerations (VPF) Roy Hubbard Agenda Understanding the three basic piping systems Design and Off-design operation Advantages and Disadvantages Low DeltaT Syndrome causes, effects, and solutions Design & Control Considerations

More information

Water terminals from 360 to 1598 m 3 /h. from 1.4 to 9.6 kw. SysQuare. Chilled water cassettes. from 1.1 to 14.0 kw

Water terminals from 360 to 1598 m 3 /h. from 1.4 to 9.6 kw. SysQuare. Chilled water cassettes. from 1.1 to 14.0 kw Water terminals from 360 to 1598 m 3 /h SysQuare Chilled water cassettes from 1.4 to 9.6 kw from 1.1 to 14.0 kw SysQuare The best way to combine low noise and energy savings ErP 2018 OFFICES HOSPITAL 6

More information

Water terminals from 360 to 1598 m 3 /h. from 1.4 to 9.6 kw. SysQuare. Chilled water cassettes. from 1.1 to 14.0 kw

Water terminals from 360 to 1598 m 3 /h. from 1.4 to 9.6 kw. SysQuare. Chilled water cassettes. from 1.1 to 14.0 kw Water terminals from 360 to 1598 m 3 /h SysQuare Chilled water cassettes from 1.4 to 9.6 kw from 1.1 to 14.0 kw SysQuare The best way to combine low noise and energy savings ErP 2018 OFFICES HOSPITAL 6

More information

Water terminals from 360 to 1598 m3/h. from 1.4 to 9.6 kw. SysQuare. Chilled water cassettes. from 1.1 to 14.0 kw

Water terminals from 360 to 1598 m3/h. from 1.4 to 9.6 kw. SysQuare. Chilled water cassettes. from 1.1 to 14.0 kw Water terminals from 360 to 1598 m3/h from 1.4 to 9.6 kw SysQuare Chilled water cassettes from 1.1 to 14.0 kw SysQuare The best way to combine low noise and energy savings ErP 2018 OFFICES HOSPITAL 6 sizes

More information

Model 140MX Flowmeter Functional Overview

Model 140MX Flowmeter Functional Overview A higher level of performance Model 14MX Flowmeter Functional Overview DESCRIPTION The Model 14MX Flowmeter (Figure 1) works on the fluid phenomenon of momentum exchange (see page 6 for details), providing

More information

PRODUCT INFORMATION. Model 140MX Flowmeter Functional Overview. PI 14-1 Rev: 1 March 2002

PRODUCT INFORMATION. Model 140MX Flowmeter Functional Overview. PI 14-1 Rev: 1 March 2002 PRODUCT INFORMATION Model 14MX Flowmeter Functional Overview PI 14-1 Rev: 1 March 22 DESCRIPTION The Model 14MX Flowmeter (Figure 1) works on the fluid phenomenon of momentum exchange (see page 6 for details),

More information

Water headers are made of reinforced plastic and the design of the spray tree ensures uniform water distribution.

Water headers are made of reinforced plastic and the design of the spray tree ensures uniform water distribution. COOLING TOWERS Main features of CT series cooling towers Standard Modural design Towers are constructed of standardized panels fabricated from heavy gauge hot-dip galvanized steel. Final assembly is made

More information

CI/SfB (57.7) 1st edition

CI/SfB (57.7) 1st edition CI/SfB (57.7) 1st edition Vent-Axia Sentinel Multivent Wholehouse Mechanical Extract Ventilation System Ventilation Lo-Carbon Energy saving solutions Sentinel Multivent continuous mechanical extract ventilation,

More information

Optimizing Central Chilled Water Systems

Optimizing Central Chilled Water Systems Optimizing Central Chilled Water Systems OPTIMIZING CENTRAL CHILLED WATER SYSTEMS kent.peterson@p2seng.com 1 O P T I M I Z I N G C E N T R A L C H I L L E D W A T E R S Y S T E M S Kent W. Peterson, PE,

More information

Air Conditioners. Technical Data. Pair application EEDEN RXS-J

Air Conditioners. Technical Data. Pair application EEDEN RXS-J Air Conditioners Technical Data Pair application EEDEN11-100 RXS-J Air Conditioners Technical Data Pair application EEDEN11-100 RXS-J TABLE OF CONTENTS RXS-J 1 Features.............................................................

More information

WATER POWERED HIGH EXPANSION FOAM GENERATORS

WATER POWERED HIGH EXPANSION FOAM GENERATORS WATER POWERED HIGH EXPANSION FOAM GENERATORS Chemguard Standard Model Water Powered (WP) High Expansion Foam Generators are designed to expand foam solution into millions of tiny stable bubbles. Expansion

More information

FILTERS. specifically designed for Ballast Water Treatment TECHNICAL SPECIFICATIONS. Vol. 2

FILTERS. specifically designed for Ballast Water Treatment TECHNICAL SPECIFICATIONS. Vol. 2 FILTERS specifically designed for Treatment TECHNICAL SPECIFICATIONS Vol. 2 Single Screen Filters For flowrates up to 1350 m 3 /h (6000 gpm), Moss Hydro offers 8 single screen filter sizes: 1.0 1.4 1.7

More information

Sample Reports. for. HAP v4.90 Example Problem

Sample Reports. for. HAP v4.90 Example Problem Sample Reports for HAP v4.90 Example Problem December, 2014 Carrier Software Systems Copyright 2014 Carrier Corporation, All Rights Reserved Introduction This document contains reports generated using

More information

Milwaukee, WI. Darron Rempel

Milwaukee, WI. Darron Rempel Application of Hydronic Radiant and Beam Systems ASHRAE Region IV Conference Milwaukee, WI May 14, 2010 Darron Rempel darronr@price hvac hvac.comcom Introduction Topics covered: o Theory of using water

More information

Optimized System for Your Bottom Line. Trane Training Class 1 Dec, 2017

Optimized System for Your Bottom Line. Trane Training Class 1 Dec, 2017 Optimized System for Your Bottom Line Trane Training Class 1 Dec, 2017 Total Cost of Ownership Setting your system for great payback Where is money spent over a 30 year lifetime? First Cost 4.9% Service

More information

Air Conditioning. Technical Data EEDEN RXS-L

Air Conditioning. Technical Data EEDEN RXS-L Air Conditioning Technical Data EEDEN15-100 RXS-L TABLE OF CONTENTS RXS-L 1 Features............................................................. 2 2 Specifications.......................................................

More information

Using Simulation Model to Reduce System Design Time and Cost

Using Simulation Model to Reduce System Design Time and Cost Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Using Simulation Model to Reduce System Design Time and Cost Vijay Bahel

More information

Calculating the Efficiency of Energy Recovery Ventilation and its Effect on Efficiency and Sizing of Building HVAC Systems

Calculating the Efficiency of Energy Recovery Ventilation and its Effect on Efficiency and Sizing of Building HVAC Systems AHRI Guideline V (I-P) 20 Guideline for Calculating the Efficiency of Energy Recovery Ventilation and its Effect on Efficiency and Sizing of Building HVAC Systems IMPORTANT SAFETY DISCLAIMER AHRI does

More information

Steam Cooling Systems and Hybrid Cooling. Andrew G. Howell Xcel Energy

Steam Cooling Systems and Hybrid Cooling. Andrew G. Howell Xcel Energy Steam Cooling Systems and Hybrid Cooling Andrew G. Howell Xcel Energy Steam Cooling Systems Once-through Recirculating Cooling Tower Direct Dry Cooling (air-cooled condenser) Indirect Dry Cooling (Heller)

More information

4DHP MULTI-ZONE PRODUCT SPECIFICATIONS OUTDOOR UNITS INDOOR UNITS 4DHP MULTI-ZONE DWM WALL MOUNTED CEILING CASSETTE DUCTED UNIT

4DHP MULTI-ZONE PRODUCT SPECIFICATIONS OUTDOOR UNITS INDOOR UNITS 4DHP MULTI-ZONE DWM WALL MOUNTED CEILING CASSETTE DUCTED UNIT DHP MULTI-ZONE PRODUCT SPECIFICATIONS UP TO SEER UP TO DUCTLESS HEAT PUMP SYSTEMS UNITS FORM NO. DHPMULTI-00 (0/07) DHP MULTI-ZONE 8K / 0K / 6K / 8K Mid Efficiency (- SEER) Matches with all indoor units

More information

manufacturer, such as low water flow rates or extreme temperatures. This may happen

manufacturer, such as low water flow rates or extreme temperatures. This may happen 5.8. Treatment of Extreme Operating Conditions As discussed in Chapter 4, the model may encounter conditions not intended by the manufacturer, such as low water flow rates or extreme temperatures. This

More information

ELFOSpace WALL3. Technical Bulletin. Water terminal unit for indoor installation, wall-mounted CFW RANGE. DC Brushless Motor

ELFOSpace WALL3. Technical Bulletin. Water terminal unit for indoor installation, wall-mounted CFW RANGE. DC Brushless Motor Technical Bulletin BT16N008GB-04 ELFOSpace WALL Water terminal unit for indoor installation, wall-mounted CFW 00.0 021.0 RANGE DC Brushless Motor High standards of efficiency and low noise New design Electronic

More information

EBP. Product Specifications. EBP Fan Coils 2 THRU 5 TONS SPLIT SYSTEM FEATURES

EBP. Product Specifications. EBP Fan Coils 2 THRU 5 TONS SPLIT SYSTEM FEATURES ENVIRONMENTALLY SOUND REFRIGERANT EBP Product Specifications EBP Fan Coils 2 THRU 5 TONS SPLIT SYSTEM FEATURES Multipoise design for maximum versatility 2 speed motor in 24 and 36 sizes 3 speed motor in

More information

OBJECT SYSTEM Figure 1 shows the object air conditioning system. Flesh outdoor air is supplied to desiccant system directly or via earth tube dependin

OBJECT SYSTEM Figure 1 shows the object air conditioning system. Flesh outdoor air is supplied to desiccant system directly or via earth tube dependin Study On Performance Evaluation And Modeling Of Temperature And Humidity Independent Control Of Air Conditioning System Based On Operation Data M. Ukai 1,*, H. Tanaka 2, M. Okumiya 1 and H. Tanaka 1 1

More information

Sample Reports. for. HAP v4.80 Example Problem

Sample Reports. for. HAP v4.80 Example Problem Sample Reports for HAP v4.80 Example Problem October, 2013 Carrier Software Systems Copyright 2013 Carrier Corporation, All Rights Reserved Introduction This document contains reports generated using the

More information

Compressed Air Principals and Self-Assessment Tools. Jeff Becker, MnTAP Technical Director June 28, 2011 for EPA Region 7

Compressed Air Principals and Self-Assessment Tools. Jeff Becker, MnTAP Technical Director June 28, 2011 for EPA Region 7 Compressed Air Principals and Self-Assessment Tools Jeff Becker, MnTAP Technical Director June 28, 2011 for EPA Region 7 Agenda MnTAP Intro Compressed air basics Fundamentals Equipment and power curves

More information

ADVANTAGE PLUS Pass-Thru Endoscope Reprocessing System USER MANUAL SITE REQUIREMENTS WASHER-DISINFECTOR ENDOSCOPE DISINFECTION SYSTEM - NORTH AMERICA

ADVANTAGE PLUS Pass-Thru Endoscope Reprocessing System USER MANUAL SITE REQUIREMENTS WASHER-DISINFECTOR ENDOSCOPE DISINFECTION SYSTEM - NORTH AMERICA ADVANTAGE PLUS Pass-Thru Endoscope Reprocessing System 1 USER MANUAL SITE REQUIREMENTS WASHER-DISINFECTOR ENDOSCOPE DISINFECTION SYSTEM - NORTH AMERICA 2 MEDIVATORS ADVANTAGE ADVANTAGE PLUS ENDORA INTERCEPT

More information

FUNDAMENTALS OF CHILLED BEAMS ANSI/ASHRAE STANDARD , METHODS OF TESTING CHILLED BEAMS

FUNDAMENTALS OF CHILLED BEAMS ANSI/ASHRAE STANDARD , METHODS OF TESTING CHILLED BEAMS FUNDAMENTALS OF CHILLED BEAMS ANSI/ASHRAE STANDARD 200-2015, METHODS OF TESTING CHILLED BEAMS NEMIC 2017 Hello! I am Davor Novosel I am here because I love to share what I know about chilled beams with

More information

WHY IS THERE A NEED FOR MORE ACCURACY IN DRY KILN CONTROL

WHY IS THERE A NEED FOR MORE ACCURACY IN DRY KILN CONTROL WHY IS THERE A NEED FOR MORE ACCURACY IN DRY KILN CONTROL Leon Breckenridge Integrated Energy Economic Services, Inc. Yakima, Washington INTRODUCTION Section A Parameters for Measurement and Control The

More information

ENGINEERING DATA HOT WATER CAPACITIES, CALCULATIONS AND CORRECTION FACTORS

ENGINEERING DATA HOT WATER CAPACITIES, CALCULATIONS AND CORRECTION FACTORS Use the following two tables to determine 1. Heating Capacity (MBH) 2. Air Temperature (LAT) 3. Water Flow in Gallons per Minute (GPM) 4. Water Pressure Drop (WPD) in feet of water ENGINEERING DATA HOT

More information

COOLING COIL (35% ETHYLENE GLYCOL)

COOLING COIL (35% ETHYLENE GLYCOL) APPENDIX Contents A1.1 Existing Mechanical Equipment Schedules A1.2 Existing Mechanical System Schematic Drawings A2. Building Design Loads, Energy Loads and Cost Data Tables A3. Standard 62n-2001 Ventilation

More information

i-chiller COMPACT 1 to 4 kw 0 C to 30 C ic03c to ic10c RELIABILITY:

i-chiller COMPACT 1 to 4 kw 0 C to 30 C ic03c to ic10c RELIABILITY: ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within

More information

Software GHH, HEH-SR-G

Software GHH, HEH-SR-G Software GHH, HEH-SR-G Software GHH With the software GHH (Gas Humid Handling) you can calculate the Mollier chart for each combination of gas and vapor and the approximately process to recover the pollutants

More information

Inverter Drive Control and Seasonal Performance Analysis of a Single Speed Unitary Air-Source Split-System Heat Pump

Inverter Drive Control and Seasonal Performance Analysis of a Single Speed Unitary Air-Source Split-System Heat Pump Inverter Drive Control and Seasonal Performance Analysis of a Single Speed Unitary Air-Source Split-System Heat Pump Abstract Nicholas P. Salts a*, Eckhard A. Groll a a Purdue University, Ray W. Herrick

More information

ERRATA SHEET FOR ANSI/ASHRAE STANDARD (RA 2006) Method of Testing for Rating Fan-Coil Conditioners. June 8, 2006

ERRATA SHEET FOR ANSI/ASHRAE STANDARD (RA 2006) Method of Testing for Rating Fan-Coil Conditioners. June 8, 2006 ERRATA SHEET FOR ANSI/ASHRAE STANDARD 79-2002 (RA 2006) Method of Testing for Rating Fan-Coil Conditioners June 8, 2006 The corrections listed in this errata sheet apply to all copies of ANSI/ASHRAE Standard

More information

Page of ENGINEERING DATA - HOT WATER CAPACITIES, CALCULATIONS AND CORRECTION FACTORS Use the following two tables to determine

Page of ENGINEERING DATA - HOT WATER CAPACITIES, CALCULATIONS AND CORRECTION FACTORS Use the following two tables to determine ENGINEERING DATA - HOT WATER CAPACITIES, CALCULATIONS AND CORRECTION FACTORS Use the following two tables to determine The performances reflected in these tables are based on 1. Heating Capacity (MBH)

More information

YANMAR s 35 kw Combined Heat and Power System.

YANMAR s 35 kw Combined Heat and Power System. YANMAR s 35 kw Combined Heat and Power System www.yanmar-es.com YANMAR s 35 kw Combined Heat and Power System A DIFFERENT MINDSET = GAME CHANGER When thinking about heat and power for commercial buildings,

More information

AEE Water Experts. AKIKI Engineering Est. Commercial Sand Filter. Filtration

AEE Water Experts. AKIKI Engineering Est. Commercial Sand Filter. Filtration Commercial Sand Akiki Engineering Series Commercial Sand s are constructed based on efficient and economical method for reducing suspended method down to 40 microns in size on various feed water sources.

More information

4,5,6,7 008 Air Handler Goodman ARUF374316CA /230V, 1PH. 8,9,10, Furnace Unit Goodman CAPF3642C6DB /230V, 1PH

4,5,6,7 008 Air Handler Goodman ARUF374316CA /230V, 1PH. 8,9,10, Furnace Unit Goodman CAPF3642C6DB /230V, 1PH 5.0 Component List Photo # Sample no. 1 Name Manufacturer/ trademark 2 Type / model2 Serial Number Technical data and securement means 4,5,6,7 008 Air Handler Goodman ARUF374316CA 1204695348 208/230V,

More information

AQUAPROF BASIC AQUAPROF TOP ACTIVE SWITCH

AQUAPROF BASIC AQUAPROF TOP ACTIVE SWITCH AQUAPROF BASIC AQUAPROF TOP ACTIVE SWITCH SYSTEM FOR THE EXPLOITATION OF RAINWATER AQUAPROF TOP ACTIVE SWITCH AQUAPROF BASIC / AQUAPROF TOP AQUAPROF TOP Applications The AQUAPROF unit is used for the management

More information

ADVANCED HEAT EXCHANGERS SHELL & TUBE CONDENSERS

ADVANCED HEAT EXCHANGERS SHELL & TUBE CONDENSERS B ADVANCED HEAT EXCHANGERS SHELL & TUBE CONDENSERS B SHELL & TUBE CONDENSERS 2 COMPANY OVERVIE For more than 20 years, ONDA has been a leading manufacturer of process heat exchangers for the refrigeration

More information

YORK PASSIVE CHILLED BEAMS ENGINEERING GUIDE

YORK PASSIVE CHILLED BEAMS ENGINEERING GUIDE YORK PASSIVE CHILLED BEAMS ENGINEERING GUIDE Contents YORK Passive Chilled Beams 3 CB-PBE-YK / CB-PBR-YK Performance Data 5 CB-PBE-YK Dimensions 7 CB-PBR-YK Dimensions 8 Specifications 9 2 YORK Passive

More information

PERFORMANCE TESTING OF HYBRID WET-DRY COOLING SYSTEMS: INSIGHTS FROM NUMERICAL MODELING

PERFORMANCE TESTING OF HYBRID WET-DRY COOLING SYSTEMS: INSIGHTS FROM NUMERICAL MODELING Proceedings of the ASME 2014 Power Conference POWER2014 July 28-31, 2014, Baltimore, Maryland, USA POWER2014-32189 PERFORMANCE TESTING OF HYBRID WET-DRY COOLING SYSTEMS: INSIGHTS FROM NUMERICAL MODELING

More information

Professor Eugene Silberstein, CMHE SUFFOLK COUNTY COMMUNITY COLLEGE BRENTWOOD, NY CENGAGE DELMAR LEARNING CLIFTON PARK, NY

Professor Eugene Silberstein, CMHE SUFFOLK COUNTY COMMUNITY COLLEGE BRENTWOOD, NY CENGAGE DELMAR LEARNING CLIFTON PARK, NY ...WITHOUT TEARS Professor Eugene Silberstein, CMHE SUFFOLK COUNTY COMMUNITY COLLEGE BRENTWOOD, NY CENGAGE DELMAR LEARNING CLIFTON PARK, NY HVAC EXCELLENCE INSTRUCTOR CONFERENCE LAS VEGAS, NEVADA MARCH

More information

Project Information. Measure Description

Project Information. Measure Description Project Information Project ID#: CE07M016 Measure: Multiple Electric : 452,593 kwh, 8.84 kw, 39.26 kw Facility Type School Technology: Multiple Measure Description CH-1 - Chiller Plant Optimization and

More information

YORK BULKHEAD MOUNTED CHILLED BEAMS ENGINEERING GUIDE

YORK BULKHEAD MOUNTED CHILLED BEAMS ENGINEERING GUIDE YORK BULKHEAD MOUNTED CHILLED BEAMS ENGINEERING GUIDE Contents YORK Bulkhead Active Chilled Beams 3 CB-ABB-YK / CB-ABC-YK Performance Data 5 CB-ABB-YK Dimensions 10 CB-ABC-YK Dimensions 11 Specifications

More information

INFINITE ENERGY 2-199

INFINITE ENERGY 2-199 CSD-1* Manual Reset LWCO 3" AIR 3" FLUE 1" NPT RSUB-191.A Fuel Type Natural/Propane Gas Boiler FLA.92* Input BTU/hr. 200,000 / 59 kw Min. Gas Pressure Required 3" W.C.** Output BTU/hr. 183,600 / 54 kw

More information

Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende

Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende Air Conditioners Technical Data Technical Data O u t d o o r u n i t - P a i r a p p l i c a t i o n T E C H N I C A L DATA - O U T D O O R U N I T - PA I R A P P L I C AT I O N O u t d o o r u n i t -

More information

Xavier Energy Initiative

Xavier Energy Initiative Xavier Energy Initiative By Ron Perkins Report of August Site Visit To paraphrase Blaise Pascal, if I had more time I would have written a shorter report. In deference to those who do not share my enthusiasm

More information

Jones Residence Energy Cost Analysis

Jones Residence Energy Cost Analysis Jones Residence Energy Analysis for Mr. and Mrs. Joe Jones 1234 First Street Warmnister, Pa 18974 Prepared By: Jeffrey A. Smith J.A. Smith Heating & Air Cond Inc 360 Patricia Drive Warminster, Pa 18974

More information

September 22, Roy Hubbard HVAC Systems Technology

September 22, Roy Hubbard HVAC Systems Technology September 22, 2011 Roy Hubbard HVAC Systems Technology Lesson Objectives (YC-3) At the end of this session, you will understand: Understanding Chiller Energy Fundamentals Impact of VSDs (maintenance and

More information

Adapting Geothermal Flow to Heat Pump s Requirement When efficiency and flow meet

Adapting Geothermal Flow to Heat Pump s Requirement When efficiency and flow meet WELCOME! Adapting Geothermal Flow to Heat Pump s Requirement When efficiency and flow meet By PATRICK LAMBERT, P. Eng, M.M.T., CGD CEO of Geo-Energie inc. Simon Fraser University GeoExchange TM CONFERENCE

More information

2-Pipe fan coil terminal units were selected as the parallel system to handle the remaining sensible cooling load.

2-Pipe fan coil terminal units were selected as the parallel system to handle the remaining sensible cooling load. Redesign Introduction This report is an in depth analysis of the mechanical systems of the Outreach Innovation Building located in University Park, PA and the impact these changes had on other systems

More information

4,5,6,7 008 Air Handler Goodman ARUF374316CA /230V, 1PH. 8,9,10, Furnace Unit Goodman CAPF3642C6DB /230V, 1PH

4,5,6,7 008 Air Handler Goodman ARUF374316CA /230V, 1PH. 8,9,10, Furnace Unit Goodman CAPF3642C6DB /230V, 1PH 5.0 Component List Photo # Sample no. 1 Name Manufacturer/ trademark 2 Type / model2 Serial Number Technical data and securement means 4,5,6,7 008 Air Handler Goodman ARUF374316CA 1204695348 208/230V,

More information

Cooling Tower Depot, Inc. 651 Corporate Circle, Suite 206 Golden, CO Phone (720) Fax: (720)

Cooling Tower Depot, Inc. 651 Corporate Circle, Suite 206 Golden, CO Phone (720) Fax: (720) CTD Proposal : - Project: Project Location: Cooling Tower Design Conditions and Dimensions: Water Flow Rate (gpm) 0 CTD Model # Hot Water Temp (F) 0 Cell Dimensions (ft) L x W x H Cold Water Temp (F) 0

More information

Cooling Tower Depot, Inc. 651 Corporate Circle, Suite 206 Golden, CO Phone (720) Fax: (720)

Cooling Tower Depot, Inc. 651 Corporate Circle, Suite 206 Golden, CO Phone (720) Fax: (720) CTD Proposal : - Project: Project Location: Cooling Tower Design Conditions and Dimensions: Water Flow Rate (gpm) 0 CTD Model # Hot Water Temp (F) 0 Cell Dimensions (ft) L x W x H Cold Water Temp (F) 0

More information

EFFICIENT 13 SEER 3 PHASE AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Nominal Btu/hr. Min. Circuit Ampacity 18.

EFFICIENT 13 SEER 3 PHASE AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Nominal Btu/hr. Min. Circuit Ampacity 18. ENVIRONMENTALLY SOUND REFRIGERANT H4A3 Product Specifications EFFICIENT 13 SEER 3 PHASE AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 3 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 3 phase, 60 Hz

More information

FreezeFree TM Automated Anti-Icing System GENERAL SPECIFICATIONS

FreezeFree TM Automated Anti-Icing System GENERAL SPECIFICATIONS FreezeFree TM Automated Anti-Icing System GENERAL SPECIFICATIONS I. GENERAL All FreezeFree Automated Anti-Icing Systems shall be designed and manufactured by Energy Absorption Systems, Incorporated, of

More information

The Milton S. Hershey Medical Center Academic Support Building. AE Senior Thesis Kari Anne Donovan Mechanical Option

The Milton S. Hershey Medical Center Academic Support Building. AE Senior Thesis Kari Anne Donovan Mechanical Option The Milton S. Hershey Medical Center Academic Support Building AE Senior Thesis Kari Anne Donovan Mechanical Option Presentation Outline Existing Conditions Distributed Chilled Water Feasibility Study

More information

Emergency & Disaster Relief Water Purification Equipment

Emergency & Disaster Relief Water Purification Equipment GLOBAL WATER GROUP DALLAS, TEXAS U.S.A. MANUFACTURER OF THE WORLD S BEST WATER PURIFICATION AND WASTE WATER EQUIPMENT Emergency & Disaster Relief Water Purification Equipment FOR SMALL VILLAGES THROUGHOUT

More information

Cooling Tower Operation

Cooling Tower Operation Cooling Tower Operation Forced draught cooling towers use the evaporation of a liquid (often water) into air to achieve cooling. The tower often consists of a sprinkler system which wets a high-surface-area

More information